Cut-off Values of Bacteriuria and Leukocyturia for the Diagnosis of Urinary Tract Infections in Pediatric Patients
DOI:
https://doi.org/10.24293/ijcpml.v27i1.1611Keywords:
Urinary tract infections, children, leukocyturia, bacteriuria, Sysmex UX-2000Abstract
The diagnosis of Urinary Tract Infection (UTI) in infants and children is often missed. There have been no studies on diagnostic tests using automated urine analyzer in pediatric patients. This study aimed to determine the cut-off values of bacteriuria and leukocyturia using the automated urine analyzer Sysmex UX-2000 to diagnose UTI with the gold standard of automated urine culture using VITEK 2 in pediatric patients at Dr. Moewardi Hospital, Surakarta. An observational analytical study with the cross-sectional design was during August-October 2019 at the Clinical Pathology Laboratory and Clinical Microbiology Laboratory of Moewardi Hospital, Surakarta. Eighty-four patients sample were collected. This study's dependent variable was the diagnosis of urinary tract infections in pediatric patients established with positive culture results (bacterial count of ≥ 105 CFU/mL urine). This study's independent variables were the number of urine bacteria (BACT) and the number of urine leukocytes (WBC) from urinalysis using the Sysmex UX-2000 automated urine analyzer. A diagnostic test was used for data analysis. The best cut-off value for leukocyturia was 37 cells/μL with a 61.1% sensitivity, 63.6% specificity, a positive predictive value of 31.4%; a negative predictive value of 85.7; positive likelihood ratio of 1.64; negative likelihood ratio of 0.595, and accuracy of 63%. The best cut-off for the number of bacteria was 143 cells/μL with a sensitivity of 66.7%; specificity of 71.2%, the positive predictive value of 38.7%, the negative predictive value of 88.7%; positive likelihood ratio of 2.14; negative likelihood ratio of 0.432 and an accuracy of 70.2%. A cut-off of 37 cells/μL for leukocyturia and 143 cells/μL for bacteriuria using an automated urine analyzer can be used for UTI screening in pediatric patients.
Downloads
References
Seputra KP, Tarmono Bambang SN, Chaidir AM, Irfan W, Johan R, DKK. Guideline penatalaksanaan infeksi saluran kemih dan genitalia pria 2015. Jakarta, Ikatan Ahli Urologi Indonesia, 2015; 44-57.
Musim. Enhanced urinalysis dengan urin mid-stream sebagai uji diagnostik infeksi saluran kemih pada anak [Tesis]. Yogyakarta, Program Pasca Sarjana Universitas Gadjah Mada, 2007; 1-80.
Sutanto K. Validitas dan cut-off bakteri urine berdasarkan metode flow cytometry untuk mendiagnosis infeksi bakteri saluran kemih [Tesis].
Surakarta, Program Pendidikan Dokter Spesialis Patologi Klinik Universitas Sebelas Maret, 2012; 1-70.
Sysmex Corporation. Fully automated integrated urine analyzer UX-2000 Instructions for Use. Japan, Kobe, 2011; 315-344.
Pratistha FSM, Sudhana IW, Adnyana IWL. Diagnosis cepat infeksi saluran kemih dengan menghitung
jumlah leukosituria pada urinalisis metode flow cytometry Sysmex UX-2000 dengan baku emas kultur
urin di RSUP Sanglah Denpasar. E-Jurnal Medika Udayana, 2018; 7(5): 211-216.
Bargotya M, Kumar L, Das P, Kachhap P, Sachdeva V, Monika K. Evaluation of advantages of multiple
parameters of an automated urine analyzer in clinical practice. Ann Clin Cytol Pathol, 2018; 4(5): 1110.
Giesen C, Greeno A, Thompson K. Performance of flow cytometry to screen urine for bacteria and white blood cell prior to urine culture. Clin Biochem, 2013; 4(2): 68-72.
Agpaoa VV, Mendoza JB, Fernandez AJM, Veloso JD, Bhatnagar S. Predict urinary tract infection and to
estimate causative bacterial class in a Philippine subspecialty hospital. Journal of Nephrology & Therapeutics, 2015; 194: 1-2.