Evaluation of Rapid Molecular Viral Load Monitoring with ABBOTT m-PIMATM HIV-1/2 VL

Authors

  • Veronika Juanita Maskito Department of Clinical Pathology, Integrated Laboratory Installation, Dharmais National Cancer Center, Jakarta
  • Agus Susanto Kosasih Department of Clinical Pathology, Integrated Laboratory Installation, Dharmais National Cancer Center, Jakarta
  • Lyana Setiawan Department of Clinical Pathology, Integrated Laboratory Installation, Dharmais National Cancer Center, Jakarta

DOI:

https://doi.org/10.24293/ijcpml.v30i1.2167

Keywords:

HIV viral load, Abbott m-PIMATM HIV-1/2 VL, Roche Cobas®4800 system HIV-1, POCT, PCR

Abstract

World Health Organization recommends rapid results of Human Immunodeficiency Virus (HIV) viral load by using Point of Care (POC) testing, delivering faster decision-making to prevent transmission and suppress drug resistance and greater likelihood of starting therapy if the clinic provides care and treatment services. The m-PIMATM HIV-1/2VL cartridge is an RT-PCR POC test that detects HIV-1 and HIV-2 RNA viral load, recognizing the conserved-part 5'-UTR of the HIV genome. The standard, Roche Cobas®4800 system HIV-1, targets gag and LTR regions. This study aimed to determine the correlation, sensitivity, and specificity of Abbott m-PIMATM HIV-1/2VL compared to Roche Cobas®4800 system HIV-1. A cross-sectional study at Dharmais Hospital Laboratory. EDTA plasma obtained from 200 HIV patients, consisted of 80 high-viral-load samples (>1000 copies/mL), 80 low-viral-load samples (<1000 copies/mL), and 40 undetectable-viral-load samples (<14.2 copies/mL). Kappa Cohen was used to measure the categorical correlation. Sensitivity and specificity were calculated with diagnostic test. Dharmais Ethic Committee released ethical clearance No.0132/KEPK/IX/2020. The categorical correlation of Abbott m-PIMATM HIV-1/2 VL in determining the group of high or low viral load samples was 0.948 (very strong correlation). The categorical correlation deciding whether the HIV viral load sample was high, low, or undetectable was 0.714 (strong correlation). The categorical sensitivity of Abbott m-PIMATM HIV-1/2 VL compared to Roche Cobas®4800 system HIV-1 in categorizing HIV viral load was 97.5%, specificity of 97.5%. Abbott m-PIMATM HIV-1/2 VL performance in determining HIV RNA viral load group samples has a strong correlation compared to Roche Cobas®4800 system HIV-1. A larger study is required.

Downloads

Download data is not yet available.

References

Ghosn J, Taiwo B, Seedat S, Autran B, Katlama C. HIV. Aug 25, 2018. Lancet Seminar, 2018; 392(10148): P685-697.

Kementerian Kesehatan Republik Indonesia. Hari AIDS sedunia 2016. Available from: infopublik.id/kategori/sosial-budaya/390058/data-juni-2019-penderita-hiv-aids-di-indonesia-sebanyak-349-883 (accessed Aug 25, 2020).

Ghosn J, Taiwo B, Seedat S, Autran B, Katlama C. HIV. Aug 25, 2018. Lancet Seminar, 2018; 392(10148): P685-697.

Kementerian Kesehatan Republik Indonesia. Hari AIDS sedunia 2016. Available from: infopublik.id/kategori/sosial-budaya/390058/data-juni-2019-penderita-hiv-aids-di-indonesia-sebanyak-349-883 (accessed Aug 25, 2020).

Nastri BM, Pagliano P, Zannella C, Folliero V, Masullo A, Rinaldi L, Galdiero M, Franci G. HIV and Drug-Resistant Subtypes. Microorganisms. 2023; 11(1):221. https://doi.org/10.3390/microorganisms11010221

WHO. Considerations for developing a monitoring and evaluation framework for viral load testing. April 2019. Geneva, World Health Organization. Available from: https://www.who.int/publications/i/item/WHO-CDS-HIV-19.5 (accessed July 20, 2023).

WHO. Toolkit: HIV molecular diagnostics toolkit to improve access to viral load testing and infant diagnosis. July 2019. Geneva, WHO. Available from: https://apps.who.int/iris/bitstream/handle/10665/325961/9789241516211-eng.pdf?sequence=1&isAllowed=y ((accessed July, 20, 2023).

Kemenkes RI. PNPK HK.01.07/MENKES/90/2019. 2020. Available in https://siha.kemkes.go.id/portal/files_upload/PNPK_HIV_Kop_Garuda__1_.pdf (accessed Aug 5, 2020).

World Health Organization. Consolidated guidelines on the use of antiretroviral drugs for treating and preventing HIV infection recommendations for a public health approach. Second Ed., 2016. Available from: https://www.who.int/hiv/pu (Aug 25, 2020).

World Health Organization.Updated recommendations on HIV prevention, infant diagnosis, antiretroviral initiation and monitoring. World Health Organization, 2021; 34-37.

Drain PK, Dorward J, Bender A, Lillis L, Marinucci F, et al. Point-of-care HIV viral load testing: An essential tool for a sustainable global HIV/AIDS response. Clin Microbiol Rev, 2019; 32(3): e00097-18. PMID: 31092508; PMCID: PMC6589862.

Santrach PJ. Current & future applications of point of care testing. Available from: http://wwwn.cdc.gov/cliac/pdf/addenda/cliac0207/ addendumf.pdf (accessed Aug 25, 2020).

Alere technologies GmbH. m-PIMATM HIV-1/2 VL Cartridge guide. Jun 15, 2018. Abbott. Germany.

Roche. Cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system, Roche Molecular Systems, Inc. 2020; 5-20.

Petrie A, Sabin C. Medical statistics at a Glance. London, John Wiley & Sons, 2019; 21-28, 119-122.

Rondonuwu MM. Nota Dinas: Laporan perkembangan HIV AIDS & Penyakit lnfeksi Menular Seksual (PIMS) Triwulan I Tahun 2021. Kementerian Kesehatan Republik Indonesia Direktoratjenderal Pencegahan Dan Pengendalian Penyakit 2021. Available from: https://hivaids-pimsindonesia.or.id ›file›Laporan_TW_I_2021_ FINAL1.pdf-HIV AIDS DAN PIMS ((accessed Aug 25, 2020).

Maree L, Krügel M, Reinhardt B, Glass AJ. Evaluation of the alinity m HIV-1 assay for the quantification of HIV-1 RNA plasma viral load in a high-throughput molecular laboratory in South Africa. Journal of Clinical Virology, 2020; 132: 104644.

Adams P, Vancutsem E, Nicolaizeau C, Servais JY, Pierard D, et al. Multicenter evaluation of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system for the quantification of HIV-1 plasma viral load. Journal of Clinical Virology, 2019; 114: 43–49.

Ueda S, Witaningrum AM, Khairunisa SQ, Kotaki T, Motomura K. et al. Transmission dynamics of HIV-1 subtype B strains in Indonesia. Sci Rep, 2019; 9: 13986.

Chen Y, Hora B, DeMarco T, Berba R, Register H, et al. Increased predominance of HIV-1 CRF01_AE and its recombinants in the Philippines. Journal of General Virology, 2019; 100: 511–522.

Downloads

Submitted

2023-05-31

Accepted

2023-08-07

Published

2023-11-03

How to Cite

[1]
Maskito, V.J., Kosasih, A.S. and Setiawan, L. 2023. Evaluation of Rapid Molecular Viral Load Monitoring with ABBOTT m-PIMATM HIV-1/2 VL. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY. 30, 1 (Nov. 2023), 43–48. DOI:https://doi.org/10.24293/ijcpml.v30i1.2167.

Issue

Section

Articles